Dental sterilizers are imperative to a dental practice. Also referred to as autoclaves, dental sterilizers use steam—at temperatures reaching 270° F—to completely sterilize instruments and equipment. This steam sterilization of various surgical tools and dental instruments is efficient and safe. Designed for safety as well as infection control, sterilizers lock while in use and unlock when instruments are sterile and dry. Depending on what is being sterilized an autoclave cycle can range from 6 to 30 minutes. While steam is a common method for dental instrument sterilization, some dental sterilizers use dry heat and eliminate moisture from the process. Dental autoclaves and sterilizers may be among the most used equipment in a dental practice; be sure the vendor you choose offers an extensive product warranty.
|  |  |  |
Company | SciCan | SciCan | SciCan |
Item | Bravo Autoclave | STATIM 2000 G4 Sterilizer | STATIM 5000 G4 Sterilizer |
Price | Inquire | Inquire | Inquire |
Description | The Bravo is a fractionated vacuum sterilizer that incorporates both pre-vac (to remove air) and post-vac (to help drying) cycles to ensure perfect | STATIM 2000 G4 Sterilizer has a large 3.5” high-resolution touchscreen that offers a vivid display of messages and current cycle information. The | STATIM 5000 G4 Sterilizer has a large 3.5” high-resolution touchscreen that offers a vivid display of messages and current cycle information. The |
Warranty | 2 years | 1 year | 1 year |
Type: Steam, Dry Heat, Chemical | Steam | Steam | Steam |
Pre-Programmed Cycles | Yes | Unwrapped
Wrapped
Rubber/Plastic
Heavy Duty Unwrapped / Air Drying | Unwrapped
Wrapped
Rubber/Plastic
Heavy Duty Unwrapped |
Self Program Controls | Yes | Yes | Yes |
Cycle Times and Temperature | 134° C (4 minutes)
17: Porous/Wrapped (40 minutes)
Hollow/Unwrapped (35 minutes)
Solid/Wrapped (30 minutes)
Solid/Unwrapped (22 minutes)
17V: Porous/Wrapped (35 minutes)
Hollow/Unwrapped (27 minutes)
Solid/Wrapped (24 minutes)
Solid/Unwrapped (19 minutes)
21V: Porous/Wrapped (40 minutes)
Hollow/Unwrapped (32 minutes)
Solid/Wrapped (28 minutes)
Solid/Unwrapped (23 minutes) | Unwrapped - 135 °C / 6 minutes
Wrapped - 135 °C / 14 minutes
Rubber/Plastic - 121 °C / 20 minutes | Unwrapped - 132° C (9 minutes)
Wrapped - 132° C (17.5 minutes)
Rubber/Plastic - 121° C (45 minutes)
Heavy Duty Unwrapped - 132° C (12 minutes) |
Automatic Shut off | Yes | Yes | Yes |
Unit Size | 17 / 17V: 56 x 48 x 42 cm
(22 x 9 x 16.5 inches)
21V: 63.5 x 48 x 42 cm
(25 x 19 x 16.5 inches) | 49.5 x 41.5 x 15 cm (19.5 x 16.25 x 6 inches) | 60 x 41 x 19 cm (23.6 x 16.1 x 7.5 inches) |
Cassette Internal Dimensions | 17 / 17V: 25.4 x 34.29 cm
(10 x 13.5 inches)
21V: 25.4 x 44.45 cm
(10 x 17.5 inches) | 28 x 18 x 3.5 cm (11 x 7 x 1.4 inches) | 38 x 18 x 7.5 cm (15 x 7 x 3 inches) |
Chamber Capacity | 17 / 17V: 17 L
21V: 21 L | Not Available | Not Available |
Chamber Diameter | 17 / 17 V: 25.4 cm (10 inches)
21V: 25.4 cm (10 inches) | Not Available | Not Available |
Chamber Length | 17 / 17V: 34.3 cm (13.5 inches)
21V: L 44.5 cm (17.5 inches) | Not Available | Not Available |
Weight Without Water | 17: 55 kg (121 pounds)
17V: 58 kg (128 pounds)
21V: 63 kg (139 pounds) | 21 kg (46 pounds) | 33 kg (73 pounds) |
Power Consumption | 120 volts, 1,700 watts
220/230 volts, 2,300 watts
220/240 volts, 2,300 watts | 115 volts 50/60 Hz, 15 amps
1450 watts | 115 volts 50/60 Hz, 15 amps
1,450 watts |
Optional Printer | Yes | Yes | Yes |
LCD Panel | Yes | Yes | Yes |
Get Info | Not Available | Not Available | Not Available |