Endodontic Machine Driven Files

Endodontic machine driven files, used in obturation of the root canal, can help ensure a precise and successful procedure. Some aspects to consider when purchasing an endodontic machine driven file are construction material, tip type, rake angle, tip variety and length, technique used and cross section. Most files are made of Nickel Titanium. The most popular tip type is a non-cutting tip. Most vendors offer tapered tips of a few different lengths for the perfect fit in any apical canal. A variety of techniques are used with endodontic machine driven files, a few are crown down, coronal and apical sequential. The cross-section of a file may be symmetrical, asymmetrical or triangular. Be sure to inquire about rake angle, as this may be the best indication for what type of endodontic machine driven file you are purchasing.
CompanyMedidenta InternationalColteneFKG DentaireBrasselerDentsply Sirona Endodontics
Item324 NiTi Rotary FilesHyflex CM EndoRotary FilesBioRaCe NiTi Rotary SystemEndoSequence Rotary FilesGT Series X Rotary Files
PriceInquireInquireInquireInquireInquire
DescriptionThe safe ended tip reduces the possibility of ledging or transporting the canal while the .02 taper focuses the cutting action in the coronal portion Hyflex Endodontic Files offer the right combination of design and material for a superior file. The double-fluting offers exceptional cutting The BioRaCe system has been designed to achieve the required apical sizes without the need for additional steps and additional files. If used EndoSequence is the first fourth-generation rotary file to be introduced to the endodontic market. By incorporating a patented Alternate Contact PointJust as the GT Series X files’ reduced core diameter and M-Wire NiTi construction work together to increase flexibility, several powerful advantages
MaterialNickel TitaniumNickel TitaniumNickel TitaniumNickel TitaniumNickel Titanium
Range of Tip SizesNot Available#8 - #80#15 - #40#15 - #50#20 - #40
Cross SectionDouble HelixSymmetricalTriangularAsymmetricalAsymmetrical
File ManufacturingTwistedGroundElectro-Chemical Surface TreatmentTwistedNot Available
Radial LandsYesNot AvailableNot AvailableNoYes
Tip TypeNon-CuttingNoncuttingNon-CuttingNoncuttingNon-Cutting
Rake AnglePositiveNegativeNot AvailablePositiveNot Available
Available in Hand FileYesYesNoNoNot Available
Lengths Available21 mm
25 mm
19 mm
21 mm
25 mm
31 mm
15 mm
25 mm
35 mm
40 mm
21 mm
25 mm
31 mm
21 mm
25 mm
31 mm
Technique UsedCrown DownNot AvailableCrown DownCrown DownCoronal
Recommended RPMNot AvailableNot Available500 - 600 RPMNot AvailableNot Available
Operative SequenceNot AvailableNot AvailableSS Instrumentation to File #15
Expansion of Orifice
Crown Down Technique
Finalize Apical Preparation
Not AvailableNot Available
Taper0.02Not Available0.04
0.05
0.06
0.08
0.04
0.06
0.04
0.06
0.08
Get InfoNot AvailableNot AvailableNot AvailableNot AvailableNot Available
-->