Dental Sintering Furnaces

Dental sintering furnaces are used to process dental zirconia after it has been milled into a crown, bridge, framework or other restoration. These furnaces are capable of reaching the extremely high temperatures required to sinter zirconia to its final hardness. The sintering process, which can involve pressure as well as heat, reduces the porosity and increases the density of ceramic materials such as zirconia. During the sintering process zirconia undergoes a significant amount of shrinkage. When choosing a sintering furnace for your practice or lab it is important to consider its capacity, it's pre-programmed cycles and automation features. With new options for both lab and chairside sintering, producing your own zirconia restorations is faster and easier than ever.
CompanyIvoclar Vivadent Inc.DEKEMAVITA North America
ItemProgramat S1 Sintering FurnaceAustromat uSiC FurnaceVITA ZYrcomat 6000 MS Sintering Furnace
PriceInquireInquireInquire
DescriptionThe Programat S1 is a light-weight and compact sintering furnace for the sintering of frameworks made of IPS e.max ZirCAD and other ZrO2 materials. The DEKEMA high temperature furnace AUSTROMAT µSiC is equipped with three silicon carbide heating elements to safely and consistently operate at The VITA ZYRCOMAT 6000 MS sintering furnace is capable of sintering up to 25 units as well as 9-unit bridges in 80 minutes starting from room
WarrantyNot AvailableNot Available2 Years
Voltage118 – 240 volts, 50 – 60 Hz100 - 240 volts, 50 - 60 Hz230 volts, 50 Hz
DisplayLEDLEDVITA vPad Comfort, Excellence, Clinical - LCD, Touchscreen
RequirementsNot AvailableNot AvailableVITA vPad Control Unit
Chamber Dimensions8 x 8 cm (3.15 x 3.15 inches)Not Available9 x 7 cm (3.5 x 2.8 inches)
IndicationsZrO2 Ceramic MaterialsCeramicZrO2 and Al2O3 Ceramic Materials
External Dimensions57 x 31 x 43 cm (22.4 x 12.2 x 16.3 inches)98 x 42 x 60 cm (38.6 x 16.5 x 23.6 inches)47 x 31.5 x 50 cm (18.5 x 12.4 x 19.7 inches)
Computerized Auto Control / CalibrationYesYesYes
Programmable SettingsStandard Program for Ivoclar Vivadent Materials and Other ZrO2 Materials
Free Programs
10 Stored ProgramsHighSpeed, Conventional, and User-Defined Sintering Modes
VITA vPad Comfort, Clinical - 500 Firing Programs
VITA vPad Excellence - 1,000 Firing Programs
MemoryNoYesYes
PC / Printer ConnectivityUSBUSB
Ethernet
No
Maximum Pressing / Firing Temperature1530 °C (2786 °F)1,600° C (2,912° F)1,600° C (2,912° F)
Vacuum Level500 - 1060 mbarNot AvailableNot Available
Muffle TypeNot AvailableNot AvailableQuartz
Get InfoInquireNot AvailableNot Available
-->