Dental Sintering Furnaces

Dental sintering furnaces are used to process dental zirconia after it has been milled into a crown, bridge, framework or other restoration. These furnaces are capable of reaching the extremely high temperatures required to sinter zirconia to its final hardness. The sintering process, which can involve pressure as well as heat, reduces the porosity and increases the density of ceramic materials such as zirconia. During the sintering process zirconia undergoes a significant amount of shrinkage. When choosing a sintering furnace for your practice or lab it is important to consider its capacity, it's pre-programmed cycles and automation features. With new options for both lab and chairside sintering, producing your own zirconia restorations is faster and easier than ever.
CompanyDEKEMAIvoclar Vivadent Inc.VITA North America
ItemAustromat uSiC FurnaceProgramat S1 Sintering FurnaceVITA ZYrcomat 6000 MS Sintering Furnace
PriceInquireInquireInquire
DescriptionThe DEKEMA high temperature furnace AUSTROMAT µSiC is equipped with three silicon carbide heating elements to safely and consistently operate at The Programat S1 is a light-weight and compact sintering furnace for the sintering of frameworks made of IPS e.max ZirCAD and other ZrO2 materials. The VITA ZYRCOMAT 6000 MS sintering furnace is capable of sintering up to 25 units as well as 9-unit bridges in 80 minutes starting from room
WarrantyNot AvailableNot Available2 Years
Voltage100 - 240 volts, 50 - 60 Hz118 – 240 volts, 50 – 60 Hz230 volts, 50 Hz
DisplayLEDLEDVITA vPad Comfort, Excellence, Clinical - LCD, Touchscreen
RequirementsNot AvailableNot AvailableVITA vPad Control Unit
Chamber DimensionsNot Available8 x 8 cm (3.15 x 3.15 inches)9 x 7 cm (3.5 x 2.8 inches)
IndicationsCeramicZrO2 Ceramic MaterialsZrO2 and Al2O3 Ceramic Materials
External Dimensions98 x 42 x 60 cm (38.6 x 16.5 x 23.6 inches)57 x 31 x 43 cm (22.4 x 12.2 x 16.3 inches)47 x 31.5 x 50 cm (18.5 x 12.4 x 19.7 inches)
Computerized Auto Control / CalibrationYesYesYes
Programmable Settings10 Stored ProgramsStandard Program for Ivoclar Vivadent Materials and Other ZrO2 Materials
Free Programs
HighSpeed, Conventional, and User-Defined Sintering Modes
VITA vPad Comfort, Clinical - 500 Firing Programs
VITA vPad Excellence - 1,000 Firing Programs
MemoryYesNoYes
PC / Printer ConnectivityUSB
Ethernet
USBNo
Maximum Pressing / Firing Temperature1,600° C (2,912° F)1530 °C (2786 °F)1,600° C (2,912° F)
Vacuum LevelNot Available500 - 1060 mbarNot Available
Muffle TypeNot AvailableNot AvailableQuartz
Get InfoNot AvailableInquireNot Available
-->